![]() H3 |
Color and Temperature:
Blue, Purple, Pink, Green, Golden, 3000K, 4300K, 5000K, 6000K, 8000K, 12000K, 15000K, 25000K, 30000K
Wattage and Voltage:
12V/25W, 12V/35W, 12V/40W, 12V/50W, 12V/55W
24V/25W, 24V/35W, 24V/40W, 24V/50W, 24V/55W
HID Bulb products Technical Parameter:
1. Input Voltage to detect:
High input voltage 23_+0.5V or low input voltage 6.5V_+0.5V will be protected, if the voltage is back to normal >=8V_+0.3V, the stabilizer can be restart.
2. Input Starting Current: <= 8A±0.5A (Input 12V);
3. Stable Current: 3.2A_+0.15A (Input 13V);
4. Start to the stabilization time: <= 40S (Input 8A-4A);
5. Steady shot and waterproof: Accord with auto technology-related standard;
6. Output short circuit protection:
Time <= 2S, start ballast every 2S, test 10S and the ballast is normal;
7. Output short circuit protection:
Time <= 2S, start ballast every 2S, test 10S and the ballast is normal;
8. High-temperature aging test:
With high temperature 105℃ aging of 10 hours with a load, the ballast is normal;
9. Low-temperature test:
After placing 4 hours in the low temperature -40℃, the ballast can start normally;
10. Continuous turning on and off the Xenon lamp:
Starting time just want 1s, and test 20s then the ballast is normal;
11. Continuous opening:
Don’t take the load to start ballast, test 10s (5 times), the ballast is normal;
12. Continuous short-circuit:
Do not take the load to start ballast every 1s, test 10s (5 times), and then the ballast is normal;
13. Continuous working:
Continuous with xenon lamp, after 7 days the ballast is normal;
14. Load-adaptive test:
Access all kinds of xenon lamp (including the brand, a variety of aging xenon lamp) the ballast works properly;
15. EMC/EMI:
Accord with the car-related standards and will not affect a vehicle’s computer Wrench and radio. |